Product Details:
Contact Now
Chat Now
|
Seal Material: | Nitrile, Viton, Or PTFE | Valve Body Style: | 2-way Or 3-way |
---|---|---|---|
Type: | Mechanical | Operating Temperature: | Up To 200°C |
Certifications: | ISO 9001, CE, RoHS | Flow Rate: | Up To 100 GPM |
Mounting Type: | Threaded Or Flanged | Material: | Metal |
Highlight: | Rexroth poppet directional control valve,M-3SEW6C3,420MG24N9K4 |
Attribute | Value |
---|---|
Seal Material | Nitrile, Viton, or PTFE |
Valve Body Style | 2-way or 3-way |
Type | Mechanical |
Operating Temperature | Up to 200°C |
Certifications | ISO 9001, CE, RoHS |
Flow Rate | Up to 100 GPM |
Mounting Type | Threaded or Flanged |
Material | Metal |
Rexroth M-3SEW6C36 420MG24N9K4 Directional Poppet Valve High Efficient Safety New
Pipeline and cleaning requirements: Pipes must be thoroughly cleaned before installation to remove contaminants. Hot bent or welded pipes need pickling.
Electrical and mechanical cooperation: Solenoid valve coil connections must be strictly checked (24V DC) to avoid burning. Mechanical zero position requires adjustment to intermediate position when no input signal is present.
Parameter control: Oil viscosity must meet requirements (37~73cSt recommended), oil temperature ≤80℃. Avoid long-term full load operation.
Regular inspection: Replace hydraulic oil after 200 hours of first operation, then every 1000 hours. Maintain oil cleanliness (NAS 1638 Level 6). Monitor sealing status and replace seals if leakage occurs.
Spool jams: Check for oil contamination and use special disassembly tools if necessary.
Solenoid fault: Measure coil resistance (standard value 20Ω±5%), check for loose or aging wiring.
Contact Person: Mr. li
Tel: 15396656017